IRRADIANCE SENSOR SILICIUM

Functionality

The irradiance sensor is used for the professional monitoring of a PV system. With the irradiance measured by the sensor element, the expected yield of a PV system can be established and compared with the actual yield. Deviations from the target yield and a performance loss of the plant can therefore be identified quickly and reliably.

 

For variants with optional integrated temperature measurement, the temperature of the sensor element is also recorded, which corresponds approximately to the module temperature.

 

The output signal is 4 to 20 mA, which means that it is particularly suitable in the industrial area.

Irradiance sensor silicium SI-420-TC-K

IRRADIANCE MEASUREMENT

 

  • Supply voltage: 12 … 28 V DC
  • Current consumption: max. 22 mA
  • Output signal:
    4 … 20 mA for
    0 … 1,200 W / m²
  • Spectral range: 340 … 1,190 nm
  • Operating temperature: - 20 … 70 °C
  • Measuring range: 0 … 1,200 W / m²
  • Protection class: IP 65
  • Accuracy: ± 5 %
  • Dimensions (H x W x D): 86 x 145 x 39 mm
Item Number Select
423.010

Irradiance sensor silicium SI-420-TC-K

Irradiance sensor silicium SI-420-TC-T-K

TEMPERATURE MEASUREMENT

 

  • Supply voltage: 12 … 28 V DC
  • Current consumption: max. 22 mA
  • Output signal:
    4 … 20 mA for
    0 … 1,200 W / m²
  • Spectral range: 340 … 1,190 nm
  • Operating temperature: - 20 … 70 °C
  • Measuring range: 0 … 1,200 W / m²
  • Protection class: IP 65
  • Accuracy: ± 5 %
  • Dimensions (H x W x D): 86 x 145 x 39 mm
Item Number Select
423.011

Irradiance sensor silicium SI-420-TC-T-K

IRRADIANCE SENSOR SILICIUM SI-RS485-TC

Functionality

The SI-RS485-TC is used to record the solar irradiance intensity. Furthermore, it can also record the module temperature of the measurement cell. With the RS485 interface, it is particularly suitable in the industrial sector, enabling in particular high line routes.

Technical Data

IRRADIANCE MEASUREMENT

 

  • Supply voltage: 12 … 28 V DC
  • Current consumption: 33.3 mA (24 V DC)
  • Output signal: RS485 Modbus
  • Spectral range: 340 … 1,190 nm
  • Operating temperature: - 20 … 70 °C
  • Measuring range: 0 … 1,400 W / m²
  • Protection class: IP 65
  • Accuracy: ± 5 %
  • Dimensions (H x W x D): 85 x 155 x 40 mm


TEMPERATURE MEASUREMENT

 

  • Output signal: RS485 Modbus
  • Measuring range: - 20 … 70 °C
  • Accuracy: ± 2 °C
    Item Number Select
    423.015

    Irradiance sensor silicium SI-RS485-TC-T